Troubleshooting, Common problems, Troubleshooting –2 – Xantrex Technology RM1012 User Manual

Page 32: Common problems –2

Advertising
background image

Troubleshooting

4–2

Troubleshooting

Common problems

The unit shuts down during operation for four main reasons:

low battery—when the battery reaches approximately 11.8 Vdc (for
loads greater than 150 watts) for more than four minutes, or 12.3 Vdc
for loads less than 150 watts.

high battery—when the battery voltage exceeds 16 Vdc

overload—when the AC load connected to the inverter exceeds the
rated load

over temperature—when the internal temperature thresholds are
reached

This table lists problems you may encounter and offers suggestions to fix
them. Refer to

Table 4-2

and

Table 4-3

for explanation of the blinking

LEDs.

Table 4-1

Troubleshooting reference

Symptom

Possible Problem

Remedy

Loads will not start when there
is no shorepower

Inverter not turned on

Batteries at low voltage

Inverter too hot

Turn the inverter on

Recharge batteries by running the
engine or connect to shorepower

Wait until inverter has cooled
down

Loads stop running almost as
soon as they start

Load is too heavy

Batteries at low voltage level

Bad battery cable or corroded
battery terminals

Batteries in poor condition

Reduce the load

Recharge batteries by running the
engine or plug into shorepower

Check cable and connectors

Test and replace, if necessary