Transfer and general specifications – Xantrex Technology RM1012 User Manual

Page 41

Advertising
background image

Transfer and general specifications

A–5

Transfer and general specifications

Temperature compensation

– 0.023 Vdc/ °C from -2 °C to 85 °C.
Below -2 °C, the charger voltage defaults to
the – 2 °C voltage

Overvoltage shutdown

Greater than or equal to 15.3 ± 0.3 Vdc

Transfer and general specifications

AC input/bypass current

20 Aac maximum continuous at 77 °F (25 °C)
Derates after 30 °C to 5 Aac at 185 °F (85 °C)

Transfer speed

10–40 ms typical

AC low voltage transfer

90 ±5 Vac

AC low voltage restart

95 ±5 Vac, 30 second delay

AC high voltage transfer

None

Standby/off consumption

< 0.7 at 12.5 Vdc with charger and inverter
both off

Operating temperature range

– 40 °F to +185 °F (– 40 °C to +85 °C)

Storage temperature range

– 40 °F to +185 °F (– 40 °C to +85 °C)

Altitude limit

15 000 feet (5000 metres)

AC neutral to ground bonding

Invert mode: AC output neutral is connected
to AC ground (chassis)
Charge mode: AC output neutral is connected
to AC input neutral

AC input neutral is always isolated form AC
ground

Charger specifications (continued)