Charger specifications – Xantrex Technology RM1012 User Manual

Page 40

Advertising
background image

Specifications

A–4

Charger specifications

All charging specifications are at nominal conditions, 77 °F (25 °C), 14.0
Vdc at 50 A charging, 120 Vac, 60 Hz unless otherwise specified.

Shutdowns and Restarts

DC low voltage shutdown

1. Battery voltage drops below 11.8 ±0.15

Vdc at heavy loads (more than 150 W) or

12.3 Vdc at light loads (less than 150 W)
for more than 4 min and 10 sec (± 30 s)

2. Battery voltage is below 10.5 ± 0.2 Vdc for

3 seconds

DC low voltage restart

12.5 ± 0.15 Vdc

DC high voltage shutdown

16.0 ± 0.2 Vdc

DC high voltage restart

Less than 16.0 Vdc, same as DC high voltage
shutdown; there is no hysteresis

Inverter specifications (continued)

Charger specifications

Charging method

• Three-stage charging with battery

temperature compensation.
See

Figure A-3

.

• Algorithm for generic flooded batteries

only

• No equalization mode

AC input voltage

100–130 Vac

AC input frequency

54–66 Hz

Minimum battery voltage

8 Vdc
The charger does not operate below this level

Maximum charger input current

13.0 Aac

rms

Maximum charge rate

50 ± 5 Adc. See

Figure A-2

Charger efficiency

Greater than 80%

Absorption charge voltage

14.3 ± 0.3 Vdc at 77 °F (25 °C)

Float charge voltage

13.4 ± 0.3 Vdc at 77 °F (25 °C)