Front Panel Display Screens and What They Mean

975-0253-01-01

5–9

Custom Screens

Two custom screens are available. The inverter does not display them unless they
are configured using using GT-View (see page 3–12). If configured, the custom
screens display as the fourth and fifth screens during the startup sequence. They
can also be viewed by tapping the unit during normal operation and fault mode.

The first custom screen is intended for the home owner to display information
such as the name or location of the PV array associated with the inverter.

The second custom screen is intended for installers, who can configure the screen
to display, for example, contact information for service.

System *3500W

Today 15.56kWh

The “*” in these two screens (see Table 5-2 and Table 5-4)
indicates that the unit is derating its output power because the
inverter heat sink temperature is above 75° C (167° F).

The asterisk only appears when the power is actually being
limited by the inverter.

Unit *1800W

Today 7.82kWh

Insufficient
Solar Energy

Indicates the GT Inverter is not producing power due to
insufficient solar energy during low light conditions in early
morning or late afternoon or when the PV array is in shade.
This screen flashes alternately with the Normal Operation
default screen.

Table 5-10 Special Message Screens

Display

Description