Chapter 6 Basic Setting

ES-315/ES-315-F User’s Guide

50

Figure 19 Basic Setting > Switch Setup

The following table describes the labels in this screen.

Table 9 Basic Setting > Switch Setup

LABEL

DESCRIPTION

Priority Queue Assignment
IEEE 802.1p defines up to eight separate traffic types by inserting a tag into a MAC-layer frame that

contains bits to define class of service. Frames without an explicit priority tag are given the default

priority of the ingress port. Use the next fields to configure the priority level-to-physical queue mapping.
The Switch has four physical queues that you can map to the 8 priority levels. On the Switch, traffic

assigned to higher index queues gets through faster while traffic in lower index queues is dropped if

the network is congested.

Priority Level (The following descriptions are based on the traffic types defined in the IEEE 802.1d

standard (which incorporates the 802.1p).

Level 7

Typically used for network control traffic such as router configuration messages.

Level 6

Typically used for voice traffic that is especially sensitive to jitter (jitter is variation in

delay).

Level 5

Typically used for video that consumes high bandwidth and is sensitive to jitter.

Level 4

Typically used for controlled load, latency-sensitive traffic such as SNA (Systems

Network Architecture) transactions.

Level 3

Typically used for “excellent effort” or better than best effort and would include

important business traffic that can tolerate some delay.

Level 2

This is for “spare bandwidth”.

Level 1

This is typically used for non-critical “background” traffic such as bulk transfers that

are allowed but that should not affect other applications and users.

Level 0

Typically used for best-effort traffic.

Apply

Click Apply to save your changes to the Switch’s run-time memory. The Switch

loses these changes if it is turned off or loses power, so use the Save link on the top

navigation panel to save your changes to the non-volatile memory when you are

done configuring.

Cancel

Click Cancel to reset the fields.

Advertising