Operating Limits

18

Operating Limits

Power Output

The PROwatt 600 Inverter will deliver 600W or 5A
continuously. This wattage rating applies to resistive loads
such as incandescent lights while the current rating applies to
reactive loads such as motors.

Input Voltage

The input voltage limits are shown in the following table.

Operating
Condition

Voltage Range

Comment

Normal

10 V–15 V

Peak Performance

12 V–14 V

Low Voltage Alarm At or below 10.7 V The audible low battery alarm sounds

and

FAULT

indicator comes on.

Low Voltage Shut
Down

Less than 10 V

The inverter shuts down to protect the
battery from being over-discharged.
It will not restart unless the input
voltage exceeds 10 V and the unit is
manually reset. You manually reset
the unit by turning it off for 4–5
seconds and then turning it back on.

High Voltage Shut
Down

At or above 15 V

The inverter shuts down to protect
itself from excessive input voltage.
The

FAULT

indicator comes on.

Note:

Although the PROwatt 600

incorporates over-voltage protection,
it can still be damaged if input
voltage exceeds 16 V.

The unit will not restart unless the
input voltage is less than 15 V and the
unit is manually reset. You manually
reset the unit by turning it off for 4–5
seconds and then turning it back on.