Remote Operation

Remote Analog Operation

Release 3.0

111

Next select analog programming as the remote control interface.

Your options are

•

Analog V & I - voltage and current programmed via the analog interface

•

Analog V - voltage programmed via the analog interface; current set via front panel

•

Analog I - current programmed via the analog interface; voltage set via front panel

Press the LCL/RMT button to begin remote operation via the analog interface.

SCPI

To select which setpoints to control via analog programming lines, use the
command:
SYST:REM:SOUR {AVOL|ACUR|AVC}

Where

•

AVOL (Analog VOLtage) selects only voltage to be programmed via the analog

programming lines

•

ACUR (Analog CURrent) selects only current to be programmed via the analog

programming lines

•

AVC (Analog Voltage and Current) selects voltage and current to be programmed

via the analog programming lines

To select the voltage level:
SYST:COMM:APR:LEV {5|10}

Where

“5” is the 0-5V range, and
“10” is the 0-10V range

To put the unit into remote control:
SYST:REM:STAT REM

Step # Do This

You Will See

1

ERROR MSGS

2

4 times

REMOTE SELECT

3

RS-232

4

or

Select desired option.

Analog V&I,
Analog V, or
Analog I

5

Setting is saved.

MENU



ENTER





ENTER