Environmental specification, Thermal specification, Humidity specification – Xantrex Technology XDC User Manual

Page 244: International approvals, Thermal specification humidity specification

Advertising
background image

Specifications and Characteristics
Environmental Specification

242

Operating Manual for XDC Series Power Supply

Environmental Specification

Thermal

Specification

Humidity

Specification

International Approvals

CE-marked units meet: EN61010-1, EN50081-2 and EN500082-2.

CSA C/US certified to C22.2 No 1010.1 and UL3111-1.

Meets USA EMC standard: FCC, part 15, class A.

Meets Canadian ECMC standard: ICES-001.

Operating Altitude

Up to 6,500 feet (2,000 m)

Storage Altitude

Up to 50,000 feet (15,000 m)

Installation Category

II (IEC 1010-1)

Polution Degree

2 (IEC 1010-1)

Operating Temperature Range

0°C–50°C

1

1. Consult the factory for operation below 0°C and above

50°C.

Storage Temperature Range

–40°C–+85°C

Operating Humidity Range < 95% RH, Non-condensing
Storage Humidity Range

< 95% RH, Non-condensing