Configure user lines, See “configure user – Xantrex Technology XDC User Manual

Page 85

Advertising
background image

Operation

Power Supply Operation

Release 3.0

83

Configure

User Lines

The USER LINES menu option lets you configure the auxiliary status lines

The Auxiliary (Aux) lines are 2 open collector outputs that can be used to monitor
the status of the power supply. The auxiliary lines are referred to as AUX A and
AUX B. See “Making Connections for Remote Control” on page 107 for details.
Each user line also has a corresponding annunciator on the front panel display to
indicate when it is on. Aux lines can be set up to report the following status
conditions:

•

None

•

Unregul: Output Unregulated

•

OVP: Over-Voltage Condition

•

UV: Under-Voltage Condition

•

OC: Over-Current Condition

•

UC: Under-Current Condition

•

OP: Over-Power Condition

•

UP: Under-Power Condition

•

AC Off: Input power has failed or is out of range

•

OTP: Over-Temperature Condition

•

Hi Temp: High-Temperature Condition

•

SenseProt: Sense Protection Tripped

•

Fold Prot: Fold Protection Tripped

•

CC: Constant Current Mode

•

CV: Constant Voltage Mode

•

CP: Constant Power Mode

•

Out ON: Output On

•

Out OFF: Output Off

To access and work with the USER LINES menu option:

Step # Do This

You Will See

1

ERROR MSGS

2

1

1. You can also press MENU again to bring up the AUX LINES option.

USER LINES

3

Aux line A

4

or

to select which

line to configure.

Aux line B

5

Cfg None

MENU



ENTER





ENTER