Table b.2, Readback commands, Table b.2 readback commands – Xantrex Technology XDC User Manual

Page 202

Advertising
background image

200

Operating Manual for

XDC Series Power Sup

ply

SCPI Command Re

fe

rence

SCPI C

omman

d Summary

Table B.2Readback Commands

Save Default Settings

*SDS
[:]SYSTem[<channel>]:SAVE:DEFault <setting_location>

Save the factory default settings.

N/A

Query Service Request
Enable

*SRE?
[:]STATus[<channel>]:SREQuest:ENABle?

Query the Service Request Enable Register
bits.

N/A

Service Request Enable

*SRE
[:]STATus[<channel>]:SREQuest:ENABle <status-enable>

Set the Service Request Enable Register
bits.

N/A

Read Status Byte

*STB?
[:]STATus[<channel>]:SBYTe[EVENt]?

Read the status byte and Master Summary
Status bit.

N/A

Trigger

*TRG

Trigger commands. Analogous to the IEEE
488.1 defined Group Execute Trigger
interface message. See IEEE 488.2 section
6.1.4.2.5

N/A

Self-Test Query

*TST?
[:]SYSTem[<channel>]:TEST?

Internal self-test and responds indicating
whether or not the device completed the
self-test without any detected errors.

N/A

Wait To Continue

*WAI
[:]SYSTem[<channel>]:WAIT

Prevents the device from executing any
further commands or queries until the
no-operation-pending flag is TRUE.(*OPC?)

N/A

Function

SCPI Command

Description

Query

Read Output Current

[:]MEASure[<channel>][:SCALar]:CURRent[:DC]?

Read output current

N/A

Read Output Power

[:]MEASure[<channel>][:SCALar]:POWer[:DC]?

Read output power

N/A

Read Output Voltage

[:]MEASure[<channel>][:SCALar][:VOLTage][:DC]?

Read output voltage

N/A

Advertising