Extended Length Installations

If the TM500A is mounted in excess of 100 feet from the inverter, an

additional wire (with a spade lugs on both ends) must be connected between
the TM500A and shunt spade lugs. This wire acts as a ground reference and
ensures the meter will read accurately.

Use the following gauge wire for the distance the TM500A is mounted

from the inverter.

Maximum Distance

Wire Gauge

250 feet

#16 AWG

400 feet

#14 AWG

630 feet

#12 AWG

1000 feet

#10 AWG

J2 TO

INVERTER

ONLY

J1 TO

SHUNT

ONLY

SPADE LUG

SPADE LUG

Interconnect for distances over

100 feet

Figure 2-6

Extended Length Ground Wire