Required Tools

• Phillips screw driver
• 3/32" and 3/16" drill bits
• Hole saw

If the TM500A will also function as a remote control (INVERTER ON/OFF),

an additional cable must be ordered. Available lengths are:

10 feet–TC/10

25 feet–TC/25

50 feet–TC/50

100 feet–TC/100

Pre-Installation

Before installing the TM500A, read all instructions and cautionary

markings located in this manual. The unit should be mounted in a clean, dry,
protected environment.

Determine the wire route to the batteries (and inverter, if the remote

INVERTER ON/OFF function is desired).

NOTE: Check for existing electrical, plumbing or other potential
areas of accidental damage prior to making cuts in structural
surfaces.

Mounting

The unit can be surface mounted (using the adaptor supplied) or flush

mounted into a rectangular opening. Provide at least one inch clearance
behind the meter circuit board for the cabling when flush mounting.

The TM500A ships in three sections:

• TM500A
• Adaptor for surface mounting
• Mounting Bracket

Figure 2-1

TM500A and Mounting Components

Trace Meter

Panel

Adaptor

Mounting