Deltec™ shunt, Mounting/wiring the shunt, 0 installation – Xantrex Technology TM500A User Manual

Page 15

Advertising
background image

9

© 2001 Xantrex Technology Inc.
P/N 973-0012-01-02 Rev. A 05/01

Deltec™ Shunt

WARNING: BEFORE WIRING THE SHUNT TO THE BATTERIES,
SWITCH THE DC DISCONNECT TO OFF AND/OR REMOVE
THE DC FUSE.

Mounting/Wiring the Shunt

The shunt connects between the inverter and batteries in the

negative (–) line (Figure 2-10).

• Mount the shunt on or near the battery enclosure close to the negative

(–) battery terminal. Use appropriate screws to secure the shunt to the
battery enclosure.

• Disconnect the NEGATIVE cable (that connects between the inverter

and battery) from the battery’s negative (–) terminal.

• Connect the free end of the negative cable to the shunt’s terminal

labeled “INVERTER.” Ensure all connections are tight.

• Connect a short length of cable (same gauge) between the battery’s

negative(–) terminal and the shunt’s terminal labeled “BAT MINUS.”
Ensure all connections are tight.

• Connect the cables and hardware to the shunt as shown in Figure 2-7.

NOTE: The cable connection must be flat against the shunt block
with nothing between it for a good connection.

Figure 2-7

Shunt Connections

To Inverter’s

Negative Terminal

To Battery’s

Negative Terminal

Shunt Hex Bolt (9/16 inch head)
Split Lock Washer
Large Washer
Cable Lug
Shunt

2.0 INSTALLATION

Advertising