4 volumes and raid, 5 disk replacement restrictions – ZyXEL Communications NSA210 User Manual

Page 156

Advertising
background image

Chapter 7 Storage

NSA210 User’s Guide

156

available but the volume can still be used. For a degraded volume, you should
replace the faulty disk as soon as possible to obtain previous performance. See
your Quick Start Guide for more information on replacing a disk.

If it’s down, then the only indication is that you can no longer transfer files to/
from the shares in the down volume.

Note: There is no explicit message from CIFS that tells users their volume is

degraded or down.

7.5.4 Volumes and RAID

Note: Back up your data before deleting or re-creating a volume!

If you originally have one disk configured as JBOD, and you then install another
disk and want to configure the two disks to use RAID 1, you should first back up
all your data on the two disks (see the Memeo Autobackup utility on the included
CD) and then restore your data later after you create the new volume type.

Below is a table that summarizes some attributes of RAID 1 as supported on the
NSA. For capacity and storage efficiency, “S” is the size of the smallest drive in the
array, and “N” is the number of drives in the array.

Performance rankings are approximations.

7.5.5 Disk Replacement Restrictions

Note: If you’re using RAID 1 and the hard disk inside the NSA fails but the eSATA

hard disk is still working, you can remove the hard disk inside the NSA and
install the eSATA hard disk inside the NSA. Your NSA runs normally again, but
you will need to have another eSATA hard disk attached to the NSA in order to
employ RAID 1.

Table 24 RAID 1 Quick Overview

RAID Level

1

Number of Disks

2

Capacity

S*N/2

Storage
Efficiency

50%

Fault Tolerance

YYYY

Availability

YYYY

Read
Performance

YYY

Write
Performance

YYY

Advertising