Drive the digital output

Note: This request requires the privilege of I/O access control.
Method: GET/POST

Syntax:
http://<servername>/cgi-bin/setdo.cgi?do1=<state>[&do2=<state>]
[&do3=<state>][&do4=<state>][&return=<return page>]

Where state is H, L. H means NC (normal close) connected with COMMON and L
means NO (normal open) connected with COMMON. The number of DO dependents
on the server type.

parameter Value

description
H – NC connected with COMMON

do<num>

<state>

L – NO connected with COMMON

return

<return page>

Redirect to the page <return page> after the
parameter is assigned. The <return page> can
be a full URL path or relative path according the
the current path. If you omit this parameter, it
will redirect to an empty page.


Example: Drive the digital output 1 to high and redirect to an empty page

http://myserver/cgi-bin/setdo.cgi?do1=H