35. TECHNICAL SPECIFICATIONS

Model MS

24 MI FF

24 FF

24 MI

24

Category

II

2H3P

II

2H3P

II

2H3P

II

2H3P

Rated heat input

kW

25,8 25,8 26,3 26,3

Reduced heat input

kW

10,6 10,6 10,6 10,6

Rated heat output

kW

24 24 24 24

kcal/h

20.600 20.600 20.600 20.600

Reduced heat output

kW

9,3 9,3 9,3 9,3

kcal/h

8.000 8.000 8.000 8.000

Useful efficiency according to directive 92/42/EEC

★★★

★★★

★★

★★

Max. water pressure in CH system

bar

3

3

3

3

Expansion vessel capacity

l

6 6 6 6

Expansion vessel pressure

bar

1

1

1

1

DHW max. water pressure

bar

8

8

DHW min. dynamic water pressure

bar

0,15 — 0,15 —

Minimum DHW flow

l/min

2,0

— 2,0

DHW output at ∆T=25 °C

l/min

13,7 — 13,7 —

DHW output at ∆T=35 °C

l/min

9,8

— 9,8

Specific output (*)

l/min

12

12

Temperature range in heating system

°C

30/85 30/85 30/85 30/85

Temperature range in DHW system

°C

35/60 35/60*** 35/60 35/60***

Type

C12-C32-C42-C52-C82-B22

B

11BS

B

11BS

Coaxial flue duct diameter

mm

60 60

-

-

Coaxial air duct diameter

mm

100 100 -

-

2-pipe flue duct diameter

mm

80 80

-

-

2-pipe air duct diameter

mm

80 80

-

-

Flue duct diameter

mm

-

- 125 125

Max. flue mass flow rate

kg/s

0,014 0,014 0,020 0,020

Min. flue mass flow rate

kg/s

0,014 0,014 0,018 0,018

Max. exhaust temperature

°C

146 146 110 110

Min. exhaust temperature

°C

116 116 85 85

NOx Class

3

3

3

3

Type of gas

G20 G20 G20 G20

G31 G31 G31 G31

Natural gas supply pressure

mbar

20

20

20

20

Propane gas supply pressure

mbar

37

37

37

37

Power supply voltage

V

230 230 230 230

Power supply frequency

Hz

50 50 50 50

Rated power supply

W

130 130 80 80

Net weight

kg

33 32 29 28

Dimensions

Height

mm

730

730

730

730

Width

mm

400

400

400

400

Depth

mm

299

299

299

299

Protection against humidity and water

(**)

IP X5D

IP X5D

IP X5D

IP X5D

(*) according to EN 625

(**) according to EN 60529
(***) with external storage boiler