INSTALLATION INSTRUCTIONS

Description of parameters

Factory settings

24 MI FF

24 FF

24 MI

24

F01

Type of boiler
10 = sealed chamber 20 = atmospheric chamber

10

10

20

20

F02

Gas used
00 = METHANE

01 = LPG
02 = METHANE (WITH DIAPHRAGM)

02

F03

Hydraulic system
00 = instantaneous appliance
03 = appliance with external storage boiler
04 = appliance for heating only

13 = preheating (24h)

14 = preheating (1h)

13

04

13

04

F04/ F05

Setting programmable relays 1 and 2 (See SERVICE instructions)
00 = no associated function

00

F06

Maximum CH setpoint (°C)
00 = 85°C - 01 = 45°C (function unavailable)

00

F07

DHW inlet priority configuration

00

01

00

01

F08

CH max. output

(0-100%)

100

F09

DHW max. output

(0-100%)

100

F10

Min. heating output

(0-100%)

00

F11

Delay prior to new ignition in CH mode
(00-10 minutes) - 00=10 seconds

03

F12

Diagnostics (See SERVICE Instructions)

--

F13-F14-F15 Factory settings

00

F16

Anti-legionella function (with F03=03)

00 = disabled

55...67 = enabled (setpoint °C)

00

F17

CH pressure sensor selection

00 = hydraulic pressure sensor

01 = hydraulic differential pressure sensor

00

F18

Manufacture information

00

21. PARAMETER SETTINGS

To set the boiler parameters, press (

) and (

) together and hold down for at least 6 seconds. When the function is

activate, the “

F01” appears on the display alternating with the value of the parameter shown.

Edit parameters
• Press (

+/–

) to scroll through the parameters;

• Press (

+/–

) to edit each parameter;

• Press

(

)

, to save the changes. “

MEM” appears on the display;

• Press

(

i

)

, to exit without saving. “ESC” appears on the display.

22. ADJUSTMENT AND SAFETY DEVICES

The boiler has been designed in full compliance with European reference standards and in particular is fitted with the

following:

• Air pressure switch (model 24 MI FF - 24 FF)

This device only allows the burner to ignite if the exhaust flue duct is in perfect working order.

In the event of one or more of the following faults:

• flue terminal obstructed

• venturi tubes obstructed

• fan blocked

• venturi tube connection - pressure switch tripped

the boiler remains on standby and error code E03 is displayed (see table in section 10).

• Fumes thermostat (model 24 MI - 24)

This device has a sensor positioned on the left section of the fumes hood and shuts off the gas flow to the main burner

if the flue is obstructed and/or if there is no draught.

In these conditions the boiler shuts down and displays error code E03 (section 10).

After eliminating the problem, press button ( ), for at least 2 seconds to re-ignite immediately.

It is forbidden to disable this safety device