Connecting the external sensor, Connecting an external storage boiler, Important – DE DIETRICH MS 24 User Manual

Page 88

Advertising
background image

88

71.03982.03 - EN

INSTALLATION INSTRUCTIONS

26. CONNECTING THE EXTERNAL SENSOR

The wiring harness leaving the control board includes two RED wires fitted with faston covers. Connect the external sensor
to these two wires.
With the external sensor connected, the “

kt” curve (Graph 2) can be changed by pressing

+/-

.

N.B.: In case of installation in an average living unit (good perimeter insulation and radiator systems), set the “

kt” climate

curve to “25”.

27. CONNECTING AN EXTERNAL STORAGE BOILER

Model 24 - 24FF

The DHW priority sensor NTC is supplied as an accessory.

CONNECTING THE STORAGE BOILER SENSOR

The boiler can be connected to an external storage boiler. Hydraulically connect the storage boiler as shown in fig. 14.
Connect the DHW priority sensor NTC to terminals 5-6 on terminal block M2. The sensitive element of the NTC sensor must
be inserted in the special well located on the storage boiler. Adjust DHW temperature (35 °C...60 °C) by pressing

+/–

.

Figure 14

KEY:

UB STORAGE BOILER

UR HEATER

V3V EXTERNAL THREE-WAY VALVE

M2 CONNECTING TERMINAL

BLOCK

SB DHW PRIORITY STORAGE

BOILER SENSOR

MR HEATING FLOW

MB STORAGE BOILER FLOW

RR HEATING / STORAGE BOILER

RETURN

IMPORTANT :

Make sure that parameter

F03 = 03 (section 21).

TM = Flow temperature range

Te = External temperature

Graph 2

TM

Te

“kt” curves

1012_0501

CG_2085 / 1101_1701