CLEANTEX CTL/ CTL AC

GB

7.3

Adjusting the suction power

You can use the suction power adjuster

[1-9]

to adapt the machine suction power to differ-
ent applications.

7.4

Applying the brake

Folding out the black brake lever

[1-13]

pre-

vents the mobile dust extractor from rolling.
To achieve this, lift the front end of the mo-
bile dust extractor slightly and push the
black brake lever downwards until it latches
into place. Push the green lever

[1-12]

again

to release.

7.5

Temperature cut-out

To prevent overheating, a temperature cut-
out switches the mobile dust extractor off
when it reaches a critical temperature.

X

Switch off the mobile dust extractor and
allow to cool for about 5 minutes.

L If the mobile dust extractor will not switch

on again, please contact a Festool service
workshop.

7.6

Changing the filter bag

Removing the filter bag

[4]

X

Open the locking clips

[2-2]

and remove

the top section of the machine

[2-1]

.

X

Remove the filter bag.

X

Dispose of the used filter bag in accor-
dance with statutory regulations.

X

Clean the dust container

[2-3]

.

Inserting the filter bag

[5]

X

Insert a new filter bag (FIS-CT 26/36) in
the inlet port of the dust container and in-
terlock it. Important: be aware that the
locking engages.

X

Replace the top section

[2-1]

and close

the locking clips

[2-2]

.

L Make sure that the filter bag is not

pinched between the top and bottom sec-
tions.

7.7

Changing the disposal bag

Removing the disposal bag

[6]

X

Open the locking clips

[2-2]

and remove

the top section of the machine

[2-1]

.

X

Close the disposal bag.

X

Remove the disposal bag.

X

Dispose of the used disposal bag in accor-
dance with statutory regulations.

X

Clean the dust container

[2-3]

.

Inserting the disposal bag

[7]

X

Insert a new disposal bag (ENS-CT26/36)
on the inlet nozzle of the container and
lock in position.
Important: The lateral openings on the
disposal bag must be positioned inside the
container. Make sure that the bolt engag-
es.

X

Place the disposal bag over the edge of
the container.

Make sure that the contacts

[10-2]

are

free.

X

Replace the top section

[2-1]

and close

the locking clips

[2-2]

.

8

Working

8.1

Handling

Hose store: after finishing work, you can
feed the suction hose through the recess

[8-

3]

and place it in the hose store. You can do

the same with the mains cable through the
other recess

[8-2]

.

SysDoc Systainer attachment system: a
Systainer can be attached to the storage
area via the two slides

[8-1]

.

8.2

AUTO

Clean - Cleaning the main

filter (only versions with Auto-
Clean)

To maintain a constant suction power when
extracting fine dust, you can adjust the fre-
quency of the automatic

[1-7]

cleaning sys-

tem in infinite variables using the rotary
knob. Always use the automatic cleaning
system in combination with a disposal bag
(in line with dust class 'L' requirements).

Before performing wet extraction tasks
or working with a filter bag, set the

[1-

7]

rotary knob to position 0.

X

Set the automatic cleaning function to the
highest setting when

[1-7]

extracting

large quantities of dust.

Manual cleaning

If the suction power decreases, clean-
ing can be started manually by turning
the switch

[1-8]

to the AC symbol po-

sitioned on either side of the switch.

We recommend cleaning the main filter
completely if severely clogged:

X

Set the suction power adjuster

[1-9]

to

the maximum setting.

X

Cover the end of the nozzle or suction
hose with your hand for 10 seconds.