Festool CTM 48 E-LE-AC B22 CLEANTEX User Manual

Page 15

Advertising
background image

CTM 48 E LE EC/B22, CTL 48 E LE EC/B22

15

GB

aged. Always replace the mains power

cable with the type specified in the spare

parts list.

– Do not expose the machine to rain.
– For reasons of safety, never operate the

machine from an unearthed socket.

– Always use the machine socket for the pur-

pose specified in the manual.

– Always use original Festool accessories.
– Pull the plug from the socket when the ma-

chine is not in use and prior to mainte-

nance and cleaning work.

– Design 22 dust extractors are suitable for

connecting to machines in Zone 22. Care

must be taken to ensure that no sources of

ignition are extracted. Conductive machine

components, including extractor hoods,

and conductive parts on machines from

protection class II must be electrostatically

earthed. The electrostatic earthing can be

routed through the dust extractor or estab-

lished using separate electrostatic earthing

equipment.

– Do not lift or transport the machine by the

handle using a crane or lifting gear.

– The device may only be operated if all fil-

ters are present and undamaged, including

the filter for the motor cooling air.

– Do not insert and remove the plug under

load.

– In an emergency (e.g. short circuit or other

electrical faults occur), switch off the ma-

chine and pull out the mains plug.

6

Operation

6.1

Initial operation

X

Open the locking clips

[2-2]

and remove

the top section of the machine

[2-1]

.

X

Remove the accessories from the dust

container

[2-3]

and the packaging!

X

Insert a filter bag in the dust container

that fulfils statutory requirements (see

chapter 7.8).

X

Replace the top section

[2-1]

and close

the locking clips

[2-2]

.

X

Attach the cable holder to the rear of the

mobile dust extractor (see Fig.

[3]

).

X

Insert the sealing plug

[1-1]

on the panel

(see Fig.

[1]

).

X

Connect the suction hose to the machine.

6.2

Switch on/off

X

Insert the plug into an earthed socket.

The use of extension cables in Zone 22

is not permitted.

The switch

[1-9]

serves as an on/off switch.

Switch position "0"
Appliance socket

[1-11]

is disconnected from

the power, mobile dust extractor is switched

off.
"MAN" switch position
Appliance socket

[1-11]

is connected to the

power, the mobile dust extractor starts.
"Auto" switch position
Appliance socket

[1-11]

is connected to the

power, the mobile dust extractor starts when

the connected tool is switched on.

7

Settings

7.1

Adjusting the hose diameter

X

Adjust the hose diameter adjuster

[1-8]

to match the diameter of the connected

hose.

L

The monitoring devices will measure the

air speed in the extractor hose correctly

as a result (see chapter 7.9).

WARNING

Unauthorised voltage or frequency!
Risk of accident

X

The mains voltage and the frequency of

the power source must correspond with

the specifications on the machine's name

plate.

X

In North America, only Festool machines

with the voltage specifications 120 V/60

Hz may be used.

CAUTION

Risk of injury from tools starting up un-

expectedly

X

Before setting the switch to the "AUTO" or

"MAN" position, make sure that the con-

nected tool is switched off.

Advertising