CTM 48 E LE EC/B22, CTL 48 E LE EC/B22

GB

Damaged safety devices and components

must be repaired or replaced in a recognised

specialist workshop, unless otherwise indi-

cated in the operating manual.
Observe the following instructions:
– A dust test must be performed at least

once a year by the manufacturer or an in-

structed person. This test may include

checks to determine whether the filter is

damaged, the machine is sealed properly

and the monitoring features are function-

ing correctly.

– During maintenance and repair work, all

components that cannot be cleaned satis-

factorily must be replaced. The old compo-

nents must be sealed in impermeable

plastic bags prior to disposal in compliance

with applicable regulations for this type of

waste.

– Provided maintenance personnel or other

persons in the vicinity are not endangered,

the user must dismantle and clean the ma-

chine prior to performing maintenance

work. Appropriate precautionary measures

include decontaminating the machine prior

to disassembly, making provisions for lo-

cally filtered forced ventilation at the loca-

tion of machine disassembly, cleaning the

maintenance area and appropriate person-

al protective equipment.

9.1

Changing the filter element

X

Open the locking clips

[2-2]

and remove

the top section of the machine

[2-1]

.

X

Turn the top section of the machine so

that the main filter is facing upwards

(Fig.

[7]

).

X

Fold over the lever

[7-3]

and remove the

retainer.

[7-2]

X

Remove the used main filter and replace

[7-1]

with a new one.

X

Dispose of the used filter in accordance

with statutory regulations.

X

Insert the retainer

[7-2]

and fold over the

lever

[7-3]

until it engages.

X

Replace the top section

[2-1]

and close

the locking clips

[2-2]

.

9.2

Changing the cooling air filter

[8]

Replace the cooling air filter if the mobile

dust extractor switches off due to excess

temperature and replace at least once a year.
L

We recommend that you always replace

the cooling air filter together with the

main filter.

X

Unscrew the cooling air cover

[8-1]

.

X

Remove the cooling air filter and replace

with a new one!

X

Close the cooling air cover.

9.3

Emptying the dust container

The dust container

[2-3]

can be emptied

once the top section has been removed.

X

After extracting fluids, clean the fill level

sensors

[9-1]

regularly with a soft cloth

and inspect for damage.

10

Accessories

Use only original Festool accessories and

Festool consumable material intended for

this machine because these components are

designed specifically for the machine. Using

accessories and consumable material from

other suppliers will most likely affect the

quality of your working results and limit any

warranty claims. Machine wear or your own

personal workload may increase depending

on the application. Protect yourself and your

machine, and preserve your warranty claims

by always using original Festool accessories

and Festool consumable material!
The order numbers for the accessories and

filters can be found in the Festool catalogue

or on the Internet at "www.festool.com".

NOTE

Motor damage

X

Never operate the extractor without a fil-

ter element fitted as the motor may be-

come damaged.

WARNING

Using non-approved accessories and

spare parts
Risk of explosion

X

Always use Festool approved accessories

and spare parts in Design 22 mobile dust

extractors - See accompanying spare

parts and accessories list.

Advertising