7.12 technical data

(the data on the unit rating plate are applicable)

Hydraulically controlled instantaneous water heaters
Type


DHF 13 C

compact

control

DHF 13 C-A

compact

control

DHF 15 C

compact

control

DHF 18 C

compact

control

DHF 21 C

compact

control

DHF 24 C

compact

control

DHF 12 C1

compact

control

DHF 13 C3

compact

control

Part no.

074301

222214

074302

074303

074304

074305

182137

185708

Rated voltage
Partial power
Rated power

Stage
Stage

••

V

kW
kW

400

6.6

13.2

400

6.6

13.2

400

7.5

15

400

9

18

400

10.5

21

400

12
24

220

8

12

230

8.8

13.2

230

6.6

13.2

Min. flow rate to activate

Stage
Stage

••

l/min
l/min

2.5
3.7

3.0
4.5

3.0
4.5

3.9
5.9

4.4
6.4

4.9

7.6

2.5
3.7

2.5
3.7

2.5
3.7

Flow rate limiter

l/min

4.5

6.5

6.5

7.0

7.5

8.0

4.5

4.5

4.5

Pressure loss*
Flow rate

MPa

l/min

0.05

3.7

0.055

4.5

0.055

4.5

0.06

5.9

0.06

6.4

0.07

7.6

0.05

3.7

0.05

3.7

0.05

3.7

Nominal water volume

l

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.6

Type of construction

closed

x

x

x

x

x

x

x

x

x

Rated overpressure

MPa

1

1

1

1

1

1

1

1

1

Weight

kg

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

Protection class to EN 60335

1

1

1

1

1

1

1

1

1

Protection mode to EN 60529

IP 24

IP 24

IP 24

IP 24

IP 24

IP 24

IP 24

IP 24

IP 24

Test mark, see unit rating plate

x

x

x

x

x

x

x

x

x

Water connection

external thread

G ½

G ½

G ½

G ½

G ½

G ½

G ½

G ½

G ½

Electrical connection

3/PE ~ 400 V

x

x

x

x

x

x

1/N/PE ~ 220 V

x

1/N/PE ~ 230 V

x

3/PE ~ 230 V

x

Max. mains impedance Z max to
EN 61000-3-11

Ω

-

-

-

-

-

0.44

0.15

0.14

0.45

Heating element

Copper tubular

heating elementr

x

x

x

x

x

x

x

x

x

Cold water inlet

°C

≤ 20

≤ 30

≤ 20

≤ 20

≤ 20

≤ 20

≤ 20

≤ 20

≤ 20

use in waters
Total alkaline earths

mol/m³

≤ 2.5

≤ 2.5

≤ 2.5

≤ 2.5

≤ 2.5

≤ 2.5

≤ 2.5

≤ 2.5

≤ 2.5

Overall hardness (earlier unit)

°d

≤ 14

≤ 14

≤ 14

≤ 14

≤ 14

≤ 14

≤ 14

≤ 14

≤ 14

Hardness range (earlier unit)

Inclusive of 2 (me-

dium hard)

x

x

x

x

x

x

x

x

x

Table 3

* Pressure drop values also apply to the minimum flow pressure in accordance with DIN 44851 / Flow rate for heating from 10 °C to 55 °C
(∆-ϑ 45 K). A pressure drop of 0.1 MPa (1 bar) is recommended for pipe network dimensioning, in line with DIN 1988 Part 3, Table 4.

7.13 Fault finding

- qualified installer

Cause

Cause

» remedy

Unit does not switch on.

Water pressure in cold water pipe too low.

Descale or replace showerhead/Perlator®.

Strainer in 3-way valve (

6) fouled.

Clean strainer (

d

, 22).

Differential pressure switch (

10, control valve MRC)

with flow rate controller does not switch on in spite
of the hot water tap being turned fully on.

Necessary switch-on quantity to switch on the hea-
ting output is not reached.

Clean strainer (

d

, 22).

Check water pressure.

Unit does not produce hot water in spite of an audible
switch-on noise by the differential pressure switch.



Safety temperature limiter (

12) has tripped, possibly

due to:

Intlet temperature too high.

Check intlet temperature.

Control valve (MRC) faulty

.

Check and if necessary replace control valve.

Rinse

heating-system of unit, in order to avoid over-hea-
ting.

Press reset button

(

13).

Element scaled up

.

De-scale or replace element.

Heating system does not heat water.

No voltage.

Check fuse (house installation).

Heating system faulty.

Replace tubular heating element heating system (

11).