7. safety

Only a qualified contractor should carry out installation, commis-

sioning, maintenance and repair of the appliance.

7.1 general safety instructions

We guarantee trouble-free function and operational reliability

only if the original accessories and spare parts intended for the

appliance are used.

7.2 instructions, standards and regulations

Note

Observe all applicable national and regional regulations

and instructions.

8. appliance description

8.1 standard delivery

Delivered with the appliance:

- Thermometer (delivered inside the control panel)

- Cold water inlet pipe with flat gasket

- Adhesive rose for DHW circulation line

- Adaptor with flat gasket for the connection of a DHW circula-

tion line

- Plastic cap

8.2 accessories

required accessories
Depending on the static pressure, safety assemblies and pressure

reducing valves are available. These type-tested safety assemblies

protect the appliance against unacceptable excess pressure.

Further accessories
If it is not possible to fit an anode rod from above, install a seg-

mented signal anode.

9. Preparations

9.1 installation site

Always install the appliance in a room free from the risk of frost

and near the draw-off point, and secure the appliance to the floor.

9.2 transport

!

Material damage

We recommend removing the cylinder casing during

transport to the installation location, to prevent it from

becoming dirty or damaged (see chapter "Installation /

Fitting the cylinder casing and DHW circulation line if

required").

10. installation

10.1 Fitting the cylinder casing and dHw circulation

line if required

Note

Fit the cylinder casing with cover before making the water

connection and, if necessary, the DHW circulation line or

the flanged immersion heater.

The plinth trim should be fitted after the tightness check.

A DHW circulation line can be fitted to the "DHW circulation"

connection (see chapter "Specification / Dimensions and connec-

tions"). Alternatively, the "DHW circulation" connection can be

used to connect a thermometer.

dismantling

f

f Remove the cover and the plinth trim of the cylinder casing

one after the other.

f

f Pull off the temperature selector on the flanged immersion

heater.

f

f Remove the control panel cover and cable grommet.