10.4.2 connection

f

f Flush the pipes thoroughly.
The max. permissible pressure must not be exceeded (see chapter

“Specification / Data table”).
ff

Install a type-tested safety valve in the cold water supply

line. Please note that, depending on the static pressure, you

may also need a pressure reducing valve.

f

f Fit the DHW outlet pipe and the cold water inlet pipe.

26

�0

2�

09

�0

03

5

1

2

1 Cold water connection

2 Cold water supply pipe

f

f Connect the cold water supply directly to the cylinder or with

the connecting pipe routed between the cylinder feet.

f

f During fitting, counterhold the fitting with an open-ended

spanner (size 36).

f

f Check the rigidity of the connecting pipe and secure it further

if required.

ff

Size the drain so that water can drain off unimpeded when

the safety valve is fully opened.

ff

Fit the discharge pipe of the safety valve with a constant

downward slope and in a room free from the risk of frost.

ff

The safety valve discharge aperture must remain open to the

atmosphere.

10.5 Power supply

WARNING Electrocution

Before any work on the appliance, disconnect all poles

from the power supply.

WARNING Electrocution

The connection to the power supply is only permissible

as a permanent connection in conjunction with the re-

movable cable entry. Ensure that the appliance can be

separated from the power supply by an isolator that dis-

connects all poles with at least 3 mm contact separation.

WARNING Electrocution

Ensure that the appliance is earthed.

!

Material damage

Observe the type plate. The specified voltage must match

the mains voltage.

f

f Pull off the temperature selector.

f

f Undo the screws at the bottom of the control panel cover and

remove the cover.

f

f Prepare the power cable and feed it through the cable grom-

met into the control panel. Select a cable with a cross-section

suited to the load of the appliance.

f

f Connect the required load in accordance with the connection

examples (see chapter "Specification / Wiring diagrams and

connections").

f

f Fit the control panel cover.

f

f Push on the temperature selector.

f

f If the power supply utility does not permit rapid heating,

cover the pushbutton with the plastic cap provided.

f

f Use a ballpoint pen to mark the selected connected load and

voltage on the type plate.

Advertising