Installation

installation

f

f Fit the cylinder casing.

f

f Fit the cable grommet and control panel cover.

f

f Push on the temperature selector.

f

f If you use the "DHW circulation" connection to install a DHW

circulation line, you need to cut an opening in the cylinder

casing near the connection (indentation in the foam) for the

DHW circulation line.

f

f Remove the thermal insulation near the connection.

f

f Route the DHW circulation line through the aperture in the

cylinder casing and fit the DHW circulation line.

f

f Insulate the "DHW circulation" connection.

f

f Insert the supplied adaptor with flat gasket and an extension.

f

f Cover the hole in the cylinder casing with the adhesive rose

supplied.

f

f Fit the cover and the plinth trim of the cylinder casing.

10.2 thermometer

26

�0

2�

09

�0

06

2

f

f Insert the thermometer as far as it will go and align it.

10.3 signal anode

!

Material damage

The appliance must not be operated without a consump-

tion indicator or with a damaged one, otherwise water

will leak out once the anode is depleted.

26

�0

2�

09

�0

06

3

1

2

1 Transport protection

2 Signal anode with consumption indicator

f

f Remove the transport protection.

f

f Check the consumption indicator for transport damage.

10.4 water connection and safety assembly

10.4.1 safety instructions

Note

Carry out all water connection and installation work in

accordance with regulations.

!

Material damage

When using plastic pipework, observe chapter "Specifi-

cation / Fault conditions".

!

Material damage

Operate the appliance only with pressure-tested taps.

cold water line
Galvanised steel, stainless steel, copper and plastic are approved

materials.
A safety valve is required.

dHw line
Stainless steel, copper and plastic pipework are approved ma-

terials.

Advertising