commissioning
11. commissioning
11.1 commissioning
f
f Open a draw-off point until the appliance has filled up and
the pipework is free of air.
f
f Adjust the flow rate. For this, observe the maximum permis-
sible flow rate with a fully opened tap (see chapter "Specifi-
cation / Data table"). If necessary reduce the flow rate at the
butterfly valve of the safety assembly.
f
f Carry out a tightness check.
f
f Turn the temperature selector to maximum temperature.
f
f Switch the mains power ON.
f
f Check the function of the appliance.
f
f Check the function of the safety assembly.
11.1.1 appliance handover
f
f Explain the appliance function to users and familiarise them
with its operation.
f
f Make the user aware of potential dangers, especially the risk
of scalding.
f
f Hand over these instructions.
11.2 recommissioning
See chapter "Commissioning".
12. settings
12.2.1 limiting the temperature selection
You can adjust the temperature selection limitation beneath the
temperature selector.
Factory setting: Limited to 60 °C
f
f Set the temperature selector to "cold" and isolate the appli-
ance from the power supply.
f
f Remove the temperature selector and the control panel
cover.
1
2
26
�0
2�
79
�0
07
0
1 Limiter disc
2 Without limiter disc, maximum 82 °C
f
f You can set the limit to 45 °C / 60 °C by rotating the limiter
disc. After removing the limiter disc, the maximum tempera-
ture can be set.
f
f Replace the control panel cover and temperature selector.
13. shutting down
f
f Disconnect the appliance from the mains at the MCB/fuse in
the fuse box.
f
f Drain the appliance. See chapter "Maintenance / Draining the
appliance".