Fanless Embedded Controller comes with

Intel Celeron M ULV 1.0GHz Processor

Example Program

1. Enable watchdog timer and set 30 sec. as
timeout interval

;-----------------------------------------------------------

Mov dx, 2eh ; Enter to extended function mode Mov
al, 87h

Out dx, al

Out dx, al

;-----------------------------------------------------------

Mov al, 07h ; Select Logical Device 8 of watchdog
timer

Out dx,al

Inc dx

Mov al, 08h

Out dx,al

;-----------------------------------------------------------

Dec dx ; Set second as counting unit

Mov al, 0f5h

Out dx,al

Inc dx

In al,dx

And al,not 08h

Out dx,al

;-----------------------------------------------------------

Dec dx ; Set timeout interval as 30seconds and start
counting

Mov al, 0f6h

Out dx,al

Inc dx

Mov al, 30

Out dx,al

;-----------------------------------------------------------

Dec dx ; Exit the extended function mode

Mov al, 0aah

Out dx,al