Troubleshooting, A. self-test error troubleshooting guidelines – ACR&Artex B406-4 User Manual

Page 47

Advertising
background image

25-62-03

Page 47 of 87

JUN 20/13

ACR ELECTRONICS, INC / ARTEX PRODUCTS

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

B406-4 (453-5004)

TASK 25-62-03-810-801

3. Troubleshooting

SUBTASK 25-62-03-810-001

A. Self-Test Error Troubleshooting Guidelines

(1)

Table 6 describes the ELT self-test LED error codes (i.e., flash codes), their probable causes,

and possible solutions. The 5-flash error is not present when the ELT is programmed with a

serial user protocol (short message).

NOTE: Upon activation, the LED will display a long single flash, which is normal. Any self-

test error codes will display following this initial flash. Do not confuse the initial flash

with a 1-flash error code. If there are multiple errors, there is a 0.5 to 1.0 second

pause between each error code.