B. ELT Troubleshooting Guidelines

(1)

Table 7 provides ELT troubleshooting guidelines for installation and operational issues.

Table 7 ELT Troubleshooting Guide

SYMPTOM

PROBABLE CAUSE

POSSIBLE SOLUTION

Remote panel status light always

on (steady)

Improper wiring

Verify wiring

Short circuit

Check for frayed insulation

Verify integrity of all crimp and

solder connections

ELT will not turn off

Battery too low to support 406

burst and causes circuit to reset

Remove battery pack to disable

ELT and replace battery pack

Turn off ELT using local switch - If ELT turns off:

Defective remote panel harness

reset circuit wiring

Check wiring continuity and

repair as necessary

Defective remote switch

Replace remote panel

If ELT does not turn off using local switch:

ELT defective

Remove battery pack to disable

ELT and return ELT to factory for

servicing