ES900 User’s Manual

55

O

PTIONAL

I

NSTALLATION

/C

ONNECTIONS

Connecting the External Time Signal

If external signal(s) are required, the addition of a relay and signal control board (not supplied)
will be necessary.

Please consult your local electrician.

When a signal is activated, the internal contacts close completing the circuit. These internal
contacts are "dry" and supply no voltage. Voltage applied to these contacts must not exceed 30
volts. An external relay must be used to activate signaling devices.

Recommended Relay and Signal Control Board

Connections

1. Open the unit. Refer to

“Open Unit” on page 3

.

2. Insert wires into two right terminals for external time signal and tighten both screws. Refer to

Insert Wires into Right Terminals

below.

Insert Wires into Right Terminals

Acroprint Relay

P/N: 01-0230-000

Acroprint Signal Control Board P/N: 10-0164-000

Be sure to unplug the unit from the wall outlet before connecting wires of the External
Time Signal. Improper connection may cause a malfunction of the unit. Also refer to

“Attaching the Wire Clamp” on page 57

to secure wires with the wire clamp.