Serial over lan configuration – Dell PowerEdge C1100 User Manual
Page 20

20
Using the Baseboard Management Controller
www
.del
l.
com |
su
ppo
rt.
d
e
ll.
co
m
To set up the actions and alerts, perform the following steps:
1 Click the Event name in the Platform Event Filters List.
The
Set Platform Events window for that event opens.
2 Set the Shutdown Action and Alert Setting for the event.
3 Repeat steps 1 and 2 for each event.
4 To enable the settings, see the platform event filters configuration procedure.
Serial Over LAN Configuration
To configure the Serial Over LAN Configuration Advanced Settings, select values for each
attribute in Table 1-22, and click
Apply Changes.
To enable and configure the
Serial Over LAN Configuration, click Return to Serial Over LAN
Configuration Page at the bottom of the window.
Table 1-21. Platform Event Filters List
Action
Description
Reboot System
When an event occurs, the system restarts (a warm boot).
Power Cycle System
When an event occurs, the system shuts down, powers off, and
restarts (a cold boot).
Power Off System
When an event occurs, the system shuts down and powers off.
Generate Alert
An alert or platform event trap is sent when the event occurs. The
email server and address to which the alert is sent, can be set in the
Configuration Email Alert Settings window.
Event trap destinations can be set in the Configuration Trap
Settings window.
Table 1-22. Serial Over LAN configuration
Item
Description
Enable Serial Over LAN
Checked indicates enabled; Unchecked indicates disabled
Baud rate
Select a IPMI data speed of 9600 bps, 19.2 kbps, 38.4 kbps, 57.6 kbps,
or 115.2 kbps
Privilege level
Select the IPMI Serial Over LAN minimum user privilege:
Administrator, Operator, or User.