To set up the actions and alerts, perform the following steps:

1 Click the Event name in the Platform Event Filters List.

The

Set Platform Events window for that event opens.

2 Set the Shutdown Action and Alert Setting for the event.
3 Repeat steps 1 and 2 for each event.
4 To enable the settings, see the platform event filters configuration procedure.

Serial Over LAN Configuration

To configure the Serial Over LAN Configuration Advanced Settings, select values for each

attribute in Table 1-22, and click

Apply Changes.

To enable and configure the

Serial Over LAN Configuration, click Return to Serial Over LAN

Configuration Page at the bottom of the window.

Table 1-21. Platform Event Filters List

Action

Description

Reboot System

When an event occurs, the system restarts (a warm boot).

Power Cycle System

When an event occurs, the system shuts down, powers off, and

restarts (a cold boot).

Power Off System

When an event occurs, the system shuts down and powers off.

Generate Alert

An alert or platform event trap is sent when the event occurs. The

email server and address to which the alert is sent, can be set in the

Configuration Email Alert Settings window.

Event trap destinations can be set in the Configuration Trap

Settings window.

Table 1-22. Serial Over LAN configuration

Item

Description

Enable Serial Over LAN

Checked indicates enabled; Unchecked indicates disabled

Baud rate

Select a IPMI data speed of 9600 bps, 19.2 kbps, 38.4 kbps, 57.6 kbps,

or 115.2 kbps

Privilege level

Select the IPMI Serial Over LAN minimum user privilege:

Administrator, Operator, or User.