Table 1-36 shows the FRU inventory device commands.
Table 1-37 shows the sensory device commands.
Enter SDR Repository Update
Mode
Storage
2Ah
O
No
Exit SDR Repository Update
Mode
Storage
2Bh
O
No
Run Initialization Agent
Storage
2Ch
O
Yes
Table 1-36. FRU Inventory Device Commands
Commands
NetFn
CMD
O/M
Supported
Get FRU Inventory Area Info
Storage
10h
M
Yes
Read FRU Inventory Data
Storage
11h
M
Yes
Write FRU Inventory Data
Storage
12h
M
Yes
Table 1-37. Sensory Device Commands
Commands
NetFn
CMD
O/M
Supported
Get Device SDR Info
S/E
20h
O
No
Get Device SDR
S/E
21h
O
No
Reserve Device SDR Repository S/E
22h
O
No
Get Sensor Reading Factors
S/E
23h
O
Yes
Set Sensor Hysteresis
S/E
24h
O
Yes
Get Sensor Hysteresis
S/E
25h
O
Yes
Set Sensor Threshold
S/E
26h
O
Yes
Get Sensor Threshold
S/E
27h
O
Yes
Set Sensor Event Enable
S/E
28h
O
Yes
Get Sensor Event Enable
S/E
29h
O
Yes
Re-arm Sensor Events
S/E
2Ah
O
Yes
Get Sensor Event Status
S/E
2Bh
O
Yes
Get Sensor Reading
S/E
2Ch
M
Yes
Set Sensor Type
S/E
2Dh
O
No
Table 1-35. SDR Repository Commands
Commands
NetFn
CMD
O/M
Supported