Using the Baseboard Management Controller

www

.del

l.

com |

su

ppo

rt.

d

e

ll.

co

m

Use a shutdown action to protect your system if a condition exists on the server beyond a specified

threshold. To specify a shutdown action for the current event, perform the following steps:

1 Select a shutdown action that occurs when the current event occurs.
2 Enable or disable alerts using the Generate Alert option. To set the mail server IP address and

Email address for alerts, click the

Email Alert Settings option in the Alerts page.

3 Click Apply Changes.
4 Click Go Back To Platform Events Page to continue setting up event alerts.

The alert setting for the current event can be enabled or disabled. The alert can be an email, an

SNMP trap, or both. To change the setting for this alert, do the following:

1 Select the Shutdown Action for this event.
2 Set the alert for the event.

a

To issue an alert for this event, select the Enable checkbox in the Generate Alert area.

b

To turn off the alert for this event, clear the Enable checkbox in the Generate Alert area.

3 Click Apply Changes.

Users

The Users page enables you to view information and configure existing iBMC users. To change the

settings for a user, click their user ID number, in the

Users list.

NOTE:

You must have Configure Users permission to configure a iBMC user; otherwise these options are

not available

Table 1-28 displays the Users list for existing iBMC users.

Table 1-27. Platform Event - Shutdown Actions

Shutdown Actions

Description

None

No action for this event.

Reboot System

When an event occurs, the system restarts (a warm boot).

Power Cycle System

When an event occurs, the system shuts down, powers off, and

restarts (a cold boot).

Power Off System

When an event occurs, the system shuts down and powers off.