MSD Digital Retard Control

PN 8975

IMPORTANT: Read the Instructions before attempting installation.

 Parts Included:

1 - Retard Control, PN 8975

4 - Mounting Screws

Note: The Digital Retard Control must be used with an MSD 6, 7, 8 or 10 Series Ignition Control. Do not use

solid core spark plug wires.

OPERATION

The MSD Digital Retard Control uses a high speed RISC microcontroller to control the timing output

signal. This controller can make extremely quick compensations to the output signals while keeping timing

accuracy to within 1°. The circuits are thoroughly debounced and isolated to create protection against

Electro Magnetic Interference (EMI).
There are four stages of retard that can be activated independently or together for a total sum of retards.

Each stage is adjustable from 0° - 9°. The maximum amount of retard is 20° even if the total of the stages

is more. There is also an optional start retard circuit that can be programmed for 5°, 10°, 15° or 20°.

MOUNTING

The Digital Retard Control can be mounted under the hood, but should be away from direct engine heat

sources. Make sure all of the wiring reaches their connections. Use the unit as a template to mark the

location of the mounting holes. Remove the unit and drill the holes using an 1/8” drill bit. Use the supplied

screws to mount the Control.

WIRING

RED

This is the On/Off wire. Connects to switched 12 volts.

BLACK

Connects to Ground.

YELLOW

Trigger output. Connects to the MSD Ignition's White Wire.

TRIGGER INPUTS

WHITE

There are two input trigger circuits.

The wires will never be connected at the same time.

Connects to points or the amplifier trigger wire.

GREEN/VIOLET

2-Pin Connector

Connects to the magnetic pickup of the distributor or crank trigger. Green is

negative, Violet is positive.

BROWN

Retard 1, Activated when removed from ground.

RETARD CONTROL WIRES

ORANGE

Retard 2, Activated when removed from ground.

GRAY

Retard 3, Activated when removed from ground.

DARK BLUE

Retard 4, Activated when removed from ground.

When more than one channel is activated at a time, the retard amounts are cumulative (Example:

4° on the first stage, 3° on the second and 3° on the third, equal a total of 10°). The total amount

of retard that can occur is 20° even if it is programmed for more.

Note: If you are not using all of the retards, set the rotary dial to 0° or ground the inactive

circuit's activation wire(s).