MSD 6530 Digital Programmable 6AL-2 Installation User Manual
Page 10

10
INSTALLATION INSTRUCTIONS
M S D
• W W W . M S D P E R F O R M A N C E . C O M • ( 9 1 5 ) 8 5 7 - 5 2 0 0 • F A X ( 9 1 5 ) 8 5 7 - 3 3 4 4
PROGRAMMABLE FEATURES
The following explains the programmable features of the PN 6530 Ignition. These instructions serve
as an overview of the features and their operation. The Pro-Data+ software also has a Help Menu
that explains many features in great detail. The features are listed in the same order that they show
on the Data Editor list in the software.
Note: If you are programming the timing functions of the ignition, the distributor will require being
locked-out.
STATS
Stat 1: This is only used with the Hand Held Monitor, PN 7550.
REV LIMITS
Up to three different rev limits can be programmed in 100 rpm increments.
RevBurn: Burnout Rev Limit. This limit is activated when 12 volts are applied to the Light Blue
wire. It is adjustable from 2,000 to 12,500 rpm.
RevLaunch: Launch Rev Limit. This limit is activated when 12 volts are applied to the Dark Blue
wire. It is adjustable from 1,000 to 12,500 rpm.
RevMax: Max Speed Rev Limit. This is the over-rev limit and is active whenever the Launch and
Burnout limits are off.
REAL TIME
MONITOR
Figure 10 Pro-Data+ Screen and Program Windows.
RUN RETARD CURVE
BOOST/RETARD MAP
MENU
TREE
GAUGES
HELP
MENU