10 installation instructions m s d – MSD 7730 Power Grid System - Controller Only Installation User Manual

Page 10

Advertising
background image

10

INSTALLATION INSTRUCTIONS

M S D  

•   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4

space on the on the Racepak system. To be compatible the user must have a Racepak Data VNet Logger

using DatLink Software v3.7.4 or higher. Default settings will send 13 channels of data to the RacePak system.

Settings:

This tab has two possible adjustments. The first setting allows a user to turn the data recording off,

if desired. The second control tells the system what to do if the SD card is full. This setting allows

the system to either stop recording or begin to write over data with the lowest recording name. By

default the system is on and will overwrite once the memory is full.

Channels:

Each available data trace within the 7730 is listed in this tab. Each trace can be disabled individually

in order to remove unneeded traces and generate smaller files. The Ignition In channel and the

Ignition Out channel are high resolution and they generate the most amount of data at high engine

rpm.

Start Recording:

The settings here tell the controller when to start recording data so that only useful information is

stored. The recorder can be started by RPM alone or by adding a function to the RPM. For example,

the default setting starts recording as soon as the Launch Rev wire is activated and the RPM is

above 3,000.

Stop Recording:

In this tab the user controls when to stop recording. The recording can be stopped by reaching a

lower rpm limit or a trigger such as a step wire signal. When stopping recording only one of these

setting values must be triggered. There is also a setting to keep recording for some time after the

trigger to ensure that all useful data is captured. Finally, there is a user set maximum recording time

limit to ensure recording stops even if the system is not triggered for any reason.

Figure 4 Wiring the Power Grid Controller to MSD 8-Plus.

MSD

CAN

LEGACY IGNITION

SWITCHED IGNITION 12V

GREEN - STEP 5

LT. GREEN - STEP 4

TAN - STEP 3

VIOLET - STEP 2

PINK - STEP 1

BLUE - LAUNCH

LT. BLUE - BURN OUT

BRN/WHITE - RPM/TIME SWITCH

WHITE - POINTS IN

GRAY - TACH

YELLOW - SHIFT LIGHT

GREEN

GREEN

VIOLET

VIOLET

SUPPLIED JUMPER

ORANGE

BLACK

RED

WHITE

ORANGE

BLACK

+

-

ORANGE

BLACK

+

-

BATTERY

BATTERY

V-NET

CABLE

Advertising