Low Battery Voltage

EngineRPM > 500 AND Vbatt <

This alert activates when there is low battery voltage

9.0 for 5 seconds

with engine RPM. Make sure the 7730 is properly

connected to battery voltage.

2

High Battery Voltage

Vbatt > 18.0

This alert activates when there is high battery voltage.

Make sure the 7730 is properly connected to battery

voltage

3

Crank Sensor

This alert activates due to weak crank sensor signal. Make

sure the crank sensor is properly located according to

the installation instructions.

5

No CAM Sync

Engine RPM > 300 AND

This alert activates when individual cylinder timing has

been configured and no optical CAM sync signal is

detected. Make sure the optical CAM sync cable is

properly connected to the 7730.

6

12V Output

Current > 3A for 10 ms

This alert activates when there is too much load on

Shutdown

the 12V bus that is used to power accessory modules.

Make sure there are no short circuits and the 12V bus is

not overloaded.

13

Low SDcard Storage

This alert activiates when an SDCard is present and there

is less than 100 MB of storage available on the card.

Remove some data from the SDCard to remove this alert.

14

SDcard Initialization

This alert activates when the 7730 cannot initialize the

SDCard. Make sure you are using the MSD factory

supplied SDCard.

15

SDcard Write Error

This alert activates when the 7730 is unable to write to

the SDCard. Make sure you are using the MSD factory

supplied SDCard.

16

SDcard Read Error

This alert activates when the 7730 is unable to read

the SDCard. Make sure you are using the MSD factory

supplied SDCard.

17

SDcard Missing

SDcard not present AND data acquisition enabled AND

Engine is running.

18

Data Acquisition

DAQ memory buffer overflow

This alert activates if the interal data acquisition memory

buffer overflows. This will cause a recording to end

prematurely. Try deactivating some data acquisition

channels. Make sure you are using the MSD factory

supplied SDCard.

19

12V Output Overcurrent Current > 2A for 10 ms

This alert occurs when there is too much load on the 12V

bus that is used to power accessory modules. Make sure

the 12V bus is not overloaded.

20

EEPROM CRC Error

This alert occurs if the 7730 is unable to recover

configuration data from its internal EEPROM memory.

The 7730 will attempt to recover a back-up stored in its

internal Flash memory. Verify your configuration settings

are correct. If this error occurs frequently, contact MSD

tech support for an RMA.

Individual Cylinder Timing Rule

Enabled AND no CAM Sync pulse

detected

SDcard present AND SDCard Free

Storage < 100 MB

SDcard present AND Error

Initializing SDCard

Error

SDcard present AND Error

writing to SDcard

SDcard present AND Error

reading to SDcard

SDcard not present AND data

a c q u i s i t i o n e n a b l e d A N D

EngineRPM > 0

Memory Overflow

Unable to read MFF data at startup

after 3 attempts

Weak Crank Sensor

Alert Alert
ID

Text

Alert Activation Conditions

Description

Voltage Low

21

EEPROM Write Error

This alert occurs if the 7730 is unable to write data to its

internal EEPROM memory. If this error occurs frequently,

contact MSD tech support.

22

Data Acquisition

This alert activates if the internal data acquisition memory

buffer reaches a critical limit. This will cause some data

acquisition channels to be automatically disabled. Try

deactivating some data acquisition channels. Make sure

you are using the MSD factory supplied SDCard.

Unable to write any data to

EEPROM after 3 attempts

Memory Protection

DAQ memory buffer reaches

90% utilization