Computation

parameters

Description

This is the number of lines of the average power spectra. Possible

selections are 1024, 2048, 4096 or 8192 lines. The FFT calculation is

done with a block size of 2*Nbr Lines. For a waterfall graph, a large

number of lines mean a poor time resolution. Conversely, greater

time resolution results in lower frequency resolution. Note that the

overlap parameter can be used to limit this problematic.

This is the time window used for the power spectrum computation.

This parameter allows adjusting the overlap between the time blocks

used for the power spectrum calculation. This parameter can be

adjusted from 0% to 90%. This parameter can be used to increase the

time resolution of the waterfall graph.

The dB/Lin. parameter allows choosing the amplitude scale format.

The choices are dB, dB(A), lin. rms, lin. peak or lin. rms

2

.

The Integration parameter allows applying a simple or double

integration in the frequency domain for an acceleration

measurement. For the simple integration option, the power spectra

are divided by jω. For the double integration option, the spectra are

divided by –ω

2

.

At the time of the computation and if the framework has a considerable amount of data, the

interface asks the user for using a spectrum averaging:

If the user clicks Yes, the software will perform a spectrum averaging to reduce the amount of data.

In this case, the time resolution of the waterfall graph will be reduced. However, the user can adjust

the averaging rate with the button Number of spectra. Then, the number of spectra and the

averaging rate can be adjusted with the following sliding control: