58

1/3 Octave Filter Linearity

The linearity of the 1/3-octave filter has been measured for both ranges (low and high). The

experimentation is done with an adaptor (ADP092) and an electric signal. The results in dB are for an

input sensitivity of 50 mV/Pa. The maximum and the minimum linear levels are measured for each

1/3 octave band along with the noise floor.

Filter Linearity (Low Range)

Frequency (Hz)

Saturation Level

(dB)

Minimum Linear

Level (dB)

Linear Dynamic

Range (dB)

Noise Floor (dB)

20

120.5

39.5

81.0

1.3

25

120.5

34.2

86.3

0.7

31.5

120.5

33.2

87.3

2.0

40

120.5

30.6

89.9

1.2

50

120.5

30.0

90.5

1.1

63

120.5

28.1

92.4

3.2

80

120.5

27.8

92.7

0.4

100

120.5

27.4

93.1

-0.4

125

120.5

27.2

93.3

1.4

160

120.5

27.0

93.5

0.0

200

120.5

26.7

93.8

0.4

250

120.5

23.4

97.1

0.7

315

120.5

24.1

96.4

1.3

400

120.5

23.5

97.0

1.8

500

120.5

23.5

97.0

2.3

630

120.5

24.0

96.5

3.2

800

120.5

24.1

96.4

3.4

1000

120.5

24.1

96.4

4.3

1250

120.5

24.5

96.0

5.2

1600

120.5

24.5

96.0

6.1

2000

120.5

24.2

96.3

7.1

2500

120.5

24.5

96.0

8.2

3150

120.5

24.6

95.9

9.2

4000

120.5

24.7

95.8

10.1

5000

120.5

25.1

95.4

11.3

6300

120.5

25.2

95.3

12.6

8000

120.5

25.8

94.7

14.0

10000

120.5

26.3

94.2

16.9