Namelist function – V-Tech DMR18 Manual User Manual

Page 18

Advertising
background image

> > D e b u g S t a t e < <

0 - # R e d i a l

2 - # E x i t s

* Back

# Save

(Search Range)

[ - - ] ~ [ - - ]

4 . O n l i n e M o n i t o r s

* Back

# Save

[ 01 ] Online

[ 02 ] Online

[ 03 ] Online

[ 04 ] Fall

[ 05 ] Online

4 # . O n l i n e M o n i t o r s

1 - # To o l s

1 . I n s t a l l e r S e t u p
2 . S e t u p
3 . C a r d M e m o r y
4 . O n l i n e M o n i t o r s
5 . O n l i n e D e v i c e s
6 . V o l t a g e M e a s u r e

Pres NO.

to select

*Back

Tools

In Debug State, press '1 #'

key

Press '4' key

Input 2 digits

monitor code

Search Range: input the monitor adress. For example,

input the range from 01 to 05. You will see the connection

status of the selected moinitors.

13. Namelist function:

DMR18 is designed to have digital keypad and big TFT screen. Its namelist was shown on

the screen and customer can do the calling operation through the digital keypad guided by

Namelist on the screen. 2 types of namelist can be shown on the screen : DT-Config namelist

and Simulate namelist.

Enter namelist page:

Check online monitors:

Send namelist to monitors

Press '9#' in standby mode to display the user namelist. Press"#" key to scroll next/last page.

and use key 1 to 8 key on each page to call the flat you want.Please refer to the DT-Config

softwre user instructions for configure the namelist.

The namelist can be sent to monitors by door station directly.Connect the door station and

montiors correctly to the system.Then press # 8012 in standby mode ,and input password

(66666666 by default) to send namelist to all the monitors.

-17-