background image

11

04/21/08 Rev D

LIIe-INST_D

TROUBLESHOOTING

SYMPTOM CAUSE

SOLUTION

Door remains closed and screen will not
come down.

Motor does not hum.

Motor hums.

a- Check breaker fuse.

b- Check wall switch.

c- Push button limit switches might be

tripped.

d- Thermal overload tripped.

e- Defective motor or wall switch.

f- Temporary binding.

g- Capacitor burned out.

a- Replace blown fuse.

b- Check wall switch connections.

Bypassing wall switch as a test.

c- Manually open trap door. See Electrical

to reset push button limit switch. Reset
Yellow button for lower limit.

d- Let motor cool down for 15 minutes.

e- Replace motor or wall switch.

f- Manually open trap door check for

binding.

g- Replace motor.

Screen will not go up.

Motor does not hum.

Motor hums.

a- Check breaker fuse.

b- Check wall switch.

c- Push button limit switches might be

tripped.

d- Thermal overload tripped.

e- Defective motor or wall switch.

f- Temporary binding.

g- Capacitor burned out.

a- Replace blown fuse.

b- Check wall switch connections.

Bypassing wall switch as a test.

c- See Electrical to reset push button limit

switch. Reset White button for upper
limit.

d- Let motor cool down for 15 minutes.

e- Replace motor or wall switch.

f- Check for binding of roller assembly.

g- Replace motor.

Coasting.

a- Defective brake.

a- Replace motor.

Trap door closed and motor hums.

Trap door not quite closed but motor stop.

a- Check Door Close Limit (DCL) switch

a- Adjust DCL switch by moving it up or

down.

Noisy operations.

a- Cyclic noise (squeaky) pattern.

b- Gear noise

a- Lubricate roller shaft and bearing at Idler

bracket with typical oil.

b- Replace motor.

ACCESSORIES INCLUDED

1

SPDT DECORA SWITCH

1

SWITCH COVER PLATE

4 MOUNTING

BRACKET

8

1/4-20 X 1” LONG HEX HEAD BOLT

8

HELICAL LOCK WASHER FOR 1/4 BOLT

8

1/4-20 HEX NUT

Advertising