UPPER LIMIT ADJUSTMENT

The upper limit for the screen is when the trap door closes to trip the DCL switch to shut off the motor. The
DCL switch may be moved up or down to adjust the closeness of the trap door. Make adjustments as necessary.

CAUTION: BE SURE THE MOTOR IS SHUT OFF WHEN THE TRAP DOOR IS CLOSED. IF THE MOTOR STILL RUNNING (HUMMING) THEN

THE DCL SWITCH MUST BE ADJUSTED TO SHUT OFF THE MOTOR.

WARNING: FAILURE TO CHECK AND CORRECT THE MOTOR SHUT OFF CONDITION AFTER THE TRAP DOOR IS CLOSED MAY

CAUSE SEVERE DAMAGE TO THE MOTOR AND VOID THE WARRANTY.

The second upper limit for the screen is set by the motor limit switch (Yellow button or Yellow hex socket).

If the screen missed the hooks of the trap door; it should come up close the screen roller and stop. It should not
be allowed to jam between the housing and the roller.

LOWER LIMIT ADJUSTMENT

WARNING: UNLESS OTHERWISE SPECIFIED AND ORDERED, STANDARD LEADER DROP IS 12 INCHES MAXIMUM. EXCEEDING THE

MAXIMUM MAY CAUSE THE SCREEN TO FALL OFF THE ROLLER AND VOID THE WARRANTY.

PUSH BUTTON LIMIT SWITCH

Key features of the push button limit switch:

⇒ The limit switch is a spring-loaded button. It works exactly like a push on/off pen.
Button pushed in - motor limit switch disengaged, free running, screen must be stopped by control

switch.

Button pushed out - motor limit switch is engaged to stop the screen at the point at which the screen

was stopped and the limit switch pushed out.