digiMax and caliMax.

411 170 1

Digital calliper digiMax, reading 0.01 mm.

Material: Non-metallic high-tech material with 50% fibre-glass content.

Scale: 5-digit digital display with 7.5 mm numeral height for easy reading.

Reading: 0.01 mm as well as 0.0005 inch.

Packaging: Plastic box with hanging attachment.

Standards: CE compliant.

Application: For outside, inside and depth measurements.

Extra: Switches off automatically after 5 minutes of non-use.

Zero setting possible in every position for quick comparison measurements.

Battery with approx. 2-year service life included.

Order-No.

29422 150

6

48

5

411 320 3

Vernier calliper caliMax, reading 0.1 mm.

Material: Non-metallic high-tech material with 50% fibre-glass content.

Scale: Vernier for millimetre and inch display.

Reading: 0.1 mm as well as 1/64 inch.

Accuracy as per DIN 862.

Packaging: Blister packed.

Application: For outside, inside and depth measurements.

Extra: Almost parallax-free reading of the measurement value.

Neon green vernier scale in with strong contrast for optimal reading.

Order-No.

27083 150

6

45

10

dialMax and dialMax ESD.

411 210 2

Analog calliper dialMax, reading 0.1 mm.

Material: Non-metallic high-tech material with 50% fibre-glass content.

Scale: Dial, diameter 35 mm.

Reading: 0.1 mm; 1 dial rotation represents 10 mm.

Accuracy as per DIN 862.

Packaging: Blister packed.

Application: For outside, inside and depth measurements.

Extra: Impact resistant dial can be recalibrated to zero.

Order-No.

27082 150

6

45

5

411 210 8

Dial calliper dialMax ESD, reading 0.1 mm.

Material: Calliper made of ESD-safe material.

Non-metallic high-tech material with 60% fibre-glass content.

Surface resistance 10

6

- 10

9

ohms.

Scale: Dial, diameter 35 mm.

Reading: 0.1 mm; 1 dial rotation represents 10 mm.

Accuracy as per DIN 862.

Packaging: Blister packed.

Standards: IEC 61340-5-1.

Application: For all work with electrostatically endangered components.

For outside, inside and depth measurements.

Extra: Measurements in ESD protection zones and at ESD workstations.

Impact resistant dial can be recalibrated to zero.

Order-No.