Outstanding functions, Service and performance, Available for three torque ranges – Wiha Tools iTorque Flyer User Manual

Page 5

Advertising
background image

www.wiha.com

5

Large digital display with numeric
display prevents reading errors

Can be set without
separate tool

ClickControl counting function records
every single use and optimises testing
equipment monitoring

Calibration alert after 5000 uses for
absolute process safety with testing
equipment monitoring

Calibration alert cycles can be individually
adjusted when ordering the product

Individual, permanent lasering of customer
information (testing equipment number,
workplace designation, company logo...)

Can be recalibrated by
Wiha Services

Outstanding

functions

•

High quality, robust plastic
metal compound handle

•

Pleasant handling thanks to
soft zones

•

Units can be switched
(Nm

↔ in.lb | Ncm ↔ in.oz)

•

Full compatibility to the Wiha
blade range

Service and

performance

•

Wide range of calibration
services offered

•

One-off testing with works
inspection protocol

•

One-off identification with
identification number

•

Complies with all relevant
standards

Available for three

torque ranges

•

40 - 150 Ncm

•

0,8 - 3,0 Nm

•

1,0 - 6,0 Nm