Velleman EVM892 User Manual

Page 12

Advertising
background image

EVM892

29.04.2010

©Velleman

nv

12

• The display will show the temperature.

Note: without the thermocouple in place, the display will show the ambient

temperature.

Measuring frequencies

Do not perform frequency measurements in circuits with voltages

> 250V.

Always be careful when working with voltages above 60Vdc or 30Vac rms.

Keep your fingers behind the probe barriers at all times during

measurement.

• Connect the black test lead to the "COM" jack and the red test lead to the

"VΩHz" jack.

• Select the "20KHz" range with the FUNCTION switch.

• Connect the test leads to the circuit under test.

• Read the measured value from the display.

Notes:

• Use a shielded cable for measuring small signals in a noisy environment (min.

visible amplitude: 0.7Vpp).

10. Specifications

This device is not calibrated when purchased!

Regulations concerning environment of use:
• Use this meter only for measurements in CAT I and CAT II environments (see

§4)

• Use this meter only in a pollution degree 2 environment (see §5)
Ideal temperature

23°C

Ideal relative humidity

75%

Max. altitude

2000m

Overvoltage/installation category

600V CAT. II

Pollution degree

Pollution degree 2

Max. voltage between terminal and
earth

600VDC or 600Vrms AC (sine wave)

Display

3 ½ digit LCD, 2 to 3 readings/sec.

Fuse protection

200mA-range: F 0.2A/250V resettable
10A-range: ceramic F10A/250V

Power supply

9V-battery 6LF22 (only use non-

rechargeable batteries)

Ranging method

manual

Polarity indication

" - " is displayed

Overrange indication

" 1. " is displayed automatically

Battery-low indication

"

" is displayed

Operating temperature

0°C to 40°C

Storage temperature

-10°C to 50°C

Dimensions

88 x 170 x 38mm

Weight 340g

(incl.

battery)