DC Voltage (V )

Range Resolution

Accuracy

200mV 100µV

± 0.8% of rdg ± 2 digits

2V 1mV

20V 10mV

200V 100mV
600V 1V

± 1.0% of rdg ± 2 digits

Input Impedance: 10MΩ for all ranges
AC Voltage (V

)

Range Resolution

Accuracy

20V 10mV

± 0.8% of rdg ± 3 digits

200V 100mV
600V 1V

± 1.2% of rdg ± 3 digits

Input Impedance: 10MΩ for all ranges

Frequency Range: 40 to 400Hz
DC Current (A )

Range Resolution

Accuracy

20mA 10µA

± 1.2% of rdg ± 2 digits

200mA 100µA ± 1.5% of rdg ± 1 digit

10A 10mA

± 2.0% of rdg ± 5 digits

Overload Protection: 0.2A/250V resettable fuse, 10A/250V fuse for 10A range

Max. Input Current: 10A (max.10 seconds every 15 minutes)
AC Current (A

)

Range Resolution

Accuracy

20mA 10µA ± 1.2% of rdg ± 2 digits

200mA 100µA ± 1.8% of rdg ± 2 digits

10A 10mA

± 3.0% of rdg ± 7 digits

Overload Protection: 0.2A/250V resettable fuse, 10A/250V fuse for 10A range
Frequency Range: 40 to 400Hz

Max. Input Current: 10A (max.10 seconds every 15 minutes)
Frequency Range: 40 to 400Hz
Resistance

Range Resolution

Accuracy

200Ω 0.1Ω

± 0.8% of rdg ± 3 digits

2kΩ

1Ω

± 0.8% of rdg ± 2 digits

20kΩ 10Ω

200kΩ 100Ω

2MΩ 1kΩ

20MΩ 10kΩ

± 1.8% of rdg ± 2 digits

Capacitance

Range Resolution

Accuracy

200nF 100pF

± 4% of rdg ± 5 digits

2µF 1nF

20µF 10nF