Velleman DVM4200 User Manual

Page 6

Advertising
background image

22.04.2011

Wh

alw

mi

4. Over

DMMs are ca

that might o

induced in a
The existing

CAT I

A C

cir
cir

CAT II

A C

an
a p

cir
env

CAT III

A C

env
ph

env
(lo

CAT IV

A C

III
No

run
use

Warning:

This device w

IV 600V / CA

related to vo

use. Refer to
This device

Protected

electronics

circuits tha

o

measure

means o

o

mono-p

domesti

CAT IV-

more th

• measurem

meter box

• measurem

CAT IV-en

bars, low-

This device

• Measurem

boxes and

e.g. circuit

undergrou

hen carrying out me

ways be aware that

ight damage the me

rvoltage/insta

ategorized dependin

ccur at the point of

system, e.g. cause
categories accordin

CAT I-rated meter i

cuits that are not d
cuits, control signa

CAT II-rated meter

d mono-phase appl

plug and circuits in

cuit is at least 10m
vironment. E.g. hou

CAT III-rated meter

vironments, as wel
ased appliances wh

vironment, and for

ow-voltage distribut

CAT IV-rated meter

-environments as w

ote that for all meas

n outdoors (either o

ed.

was designed in acc

AT III 1000V. This i

oltages and voltage

o the table above.

e is suitable for m

electronic circuits t

s circuits, control si

at are directly conn

ements on mono-p

of a plug

hase appliances an

ic environment, pro

environment. E.g.

han 10m from a dist

ments in/on low-volt

x)

ments on (fixed) mo

nvironments (e.g. m

voltage distribution

e is suitable for m

ments on distribution

d equipment/circuits

ts in sheds, garden

und wiring e.g. gard

DVM4200

6

easurements on a T

t high amplitude vo

eter.

allation categ

ng on the risk and s

f test. Transients ar

ed by lightning strik

ng EN 61010-1 are

s suitable for meas

directly connected to

ls…

is suitable for mea

liances that are con

a normal domestic

m apart from a CAT I

usehold appliances,
r is suitable for mea

l as for measureme

hich are at least 10m

measurements in o

tion boards, lighting

r is suitable for mea

well as on the prima

surements on equip

overhead or underg

cordance with EN 6

mplies that certain

peaks which can o

easurements up t

that are not directly

gnals, circuits behi

nected to mains pow

hase appliances tha

d circuits directly c

ovided that the circu

household applianc

tribution board …

tage distribution bo

ono- or poly-phased

mains outlets, electr

n boards and circuit

easurements up t

n equipment and ou

s outside or remote

houses and free-st

den lighting, pool-pu

TV set or switching

ltage pulses at the

gory

severity of transient

re short-lived bursts

ke on a power line.

:

surements on protec

o mains power, e.g

surements in CAT I

nnected to the main

environment, prov

III- or 20m apart fr

, portable tools…
asurements in CAT

ents on (fixed) mon

m apart from of a C

or on distribution le

g circuits, electric ov

asuring in CAT I-, C

ary supply level.

pment for which the

ground) a CAT IV m

1010-1 installation

restrictions in use

ccur within the env

to 1000V:

y connected to main

nd isolating transfo

wer, but limited to:

at are connected to

onnected to the ma

uit is at least 10m a

ces, portable tools,

oards (distribution b

d appliances and cir

ric ovens, lighting c

breakers).

to 600V:

utdoor installations

e from the domestic

tanding garages , o

ump...

©Velleman nv

power circuits,

test points

t overvoltage

s of energy

cted electronic

. electronics

I-environments

ns by means of

ided that the

rom a CAT IV-

I- and CAT II-

o- or poly-

CAT IV-

evel equipment

vens).

CAT II- and CAT

e supply cables

eter must be

category CAT

apply that are

vironment of

ns power, e.g.

ormer…

the mains by

ains in a normal

apart from a

light circuits at

boards behind

rcuits except in

ircuits, bus

including meter

c environment

or circuits using

Advertising