Non-contact ac voltage detector, Dc voltage, Ac voltage – Velleman DVM1500 User Manual

Page 13

Advertising
background image

DVM1500

V. 03 – 04/11/2013

13

©Velleman nv

overvoltage category 1000 V CAT II and 600 V CAT III
pollution degree

2

operating temperature 0 °C (32 °F) – 40 °C (122 °F) (< 80 % RH, < 10 °C)
storage temperature

-10 °C (14 °F) – 60 °C (140 °F) (< 70 % RH, remove

batteries!)

temperature
coefficient

0.1x/°C (< 18 °C or > 28 °C)

max. voltage between
terminals and earth

750 Vac rms or 1000 Vdc

fuse protection

μA and mA, F500mA/250V, 5 x 20 mm (10A range not
protected)

sample rate

3x/s

display

3

¾

digits LCD with automatic indication of functions

and symbols

overrange indication

yes (“OL”)

low battery indication yes (

)

polarity indication

“–” displayed automatically

data hold

yes

backlight

yes

auto power off

yes, after 15 min. Buzzer sounds after 14 min as a
warning.

power supply

3 x 1.5 V AAA batteries

dimensions

85 x 180 x 45 mm

weight (with battery) ± 280 g (incl. holster)
accessories

manual, test probes, batteries, K-type thermocouple

Non-Contact AC Voltage Detector
Sensitivity

Frequency

Distance

> 50 V

50 Hz

< 150 mm

DC Voltage
Range

Resolution

Accuracy

400 mV

0.1 mV

± (0.8 % of reading + 3 digits)

4 V

1 mV

40 V

10 mV

400 V

100 mV

1000 V

1 V

± (1.0 % of reading + 3 digits)

Input impedance: 10 MΩ
Max. input voltage: 1000 Vdc

AC Voltage
Range

Resolution

Accuracy

4 V

1 mV

± (1.0 % of reading + 3 digits)

40 V

10 mV

400 V

100 mV

Advertising