Section 8, Shuttle valve installation, Section 8 shuttle valve installation – Banks Power Twin-Turbo: Forced Induction- Twin Turbos Small Block Chevy User Manual

Page 29

Advertising
background image

96800 v.1.0

29

Note: This installation may require
assistance from a second person.
Ensure shuttle valve bore is clean and
free of debris. Temporarily install the
valve piston to ensure that it moves
freely through the bore.

1.

Install the shuttle valve cap and

gasket onto the right side of the
pressure chamber using four

1

4

-20 x

1

2

” socket bolts. Torque the

1

4

" bolts

to 30-36 in-lbs (2.5-3 ft-lbs). See
Figure 33.

2.

Place the shuttle valve piston into

the bore with the tapered end first.
See

Figure 34.

3.

Obtain four

1

4

-20 x

1

2

" socket

head bolts and have the necessary
tools handy for their installation.

4.

Slide the spring into the valve

inside the bore. Insert the spring guide
into the spring. See

Figure 35.

5.

Push on the spring guide to

compress the spring until the spring
guide flange is seated against the
pressure chamber. See

Figure 36.

Install the four

1

4

-20 x

1

2

" bolts to

hold the spring guide. Make sure to
have at least two bolts (opposite
corners) installed before releasing the
spring guide to avoid damage to the
components or personal injury. Torque
the

1

4

" bolts to 5-7 ft-lbs. Note: This

step is much easier with two people.

6.

Apply liquid Teflon to the

1

2

" NPT

threads of the

1

2

" NPT x -10 AN 90º

fitting.

7.

Install the

1

2

" NPT x -10 AN 90º

fitting into the spring guide. Tighten
the fitting leaving the -10 end facing
straight back. See

Figure 37

8.

Assemble the -10 hose with the

straight hose end on one end and the
90º hose end on the other to route

Section 8

SHUTTLE VALVE INSTALLATION

Figure 33

Advertising