Plenum Temperature Sensor

The plenum temperature sensor is

the small grey PVC junction box at-

tached by a cord to the fan/heater

control box on the master fan/heater

unit.

1. On either side of the fan/heater,

drill one 3/4” hole even with the

fan/heater unit in a valley on the

bin sidewall.

2. Insert the probe through the

3/4” hole.

3. Position the housing so the cord

exits the housing horizontally,

and the tabs fall on the sidewall

peaks.

4. Use two self drilling screws to

mount the housing to the bin

sidewall.

5. Caulk between the housing and

the sidewall to seal.

Important!

If the Top Dry is a two fan unit,

do not mount the plenum tem-

perature sensor between the two

fan/heater units.

Plenum temperature sensor on the bin sidewall.